Fancoil Falko ceiling OC Standard

XIMG00820-Falko OC 510.140_rendition1
XGRF01051-kit canalizzato 3D r03_rendition1
XIMG00819-Falko OC 510.137_rendition1
Product Code: TCM03A
Falko OC is the result of a great commitment of resources, aiming to offer a product at the forefront in terms of performance, silence, consumption and functionality. Offered with high-prevalence centrifugal fan, it has a wide range for every residential application.

Falko OC is the Fancoil for suspended ceiling installation. Thanks to the height of only 24 cm and the high efficiency exchange battery, it can be installed inside the suspended ceilings in the residential setting. The downward air intake is changeable at site into intake from behind. The condensate collection tray has DN 20 connection. The motor has three live inputs for speed selection. The frame is made of galvanized metal sheet. The air filter is removable, on the intake. Water connections, 3/4” F placed on the left side. 

sss.jpg

:All units, compliant with European directives, are provided with CE (TUV) marking and relative certificate of conformity.

 

Field of use

  • Heat, cool and dehumidify rooms.
  • Heat with high efficiency at high as well as low supply temperatures (excellent for heat pump systems).
  • Be connected to traditional boilers, condensing boilers, solar systems or heat pumps.
  • Be contained inside suspended ceilings.
  • Build simple ducted networks, even with the use of the range of available accessories, to distribute air in multiple rooms.
  • The air intake orientation can be changed at site. Can be ducted to each room or taken from a single shared grid below the unit
  •  
Dimentions

adadadvfgtghgg.jpg

All measurements are in mm:

 CODEDESCRIPTION A [mm] B [mm]
 TCM05A  FALKO 510 OC  687  894
 TCM08A  FALKO 850 OC  832  1039
 TCM14A  FALKO 1360 OC  1112  1319

 

 
Technical data

Technical data

 
    

FALKO

  

OC 510

  

TCM05A

 
 

FALKO

  

OC 850

  

TCM08A

 
 

FALKO

  

OC 1360

  

TCM14A

 

Description

Code

   

H

M

L

H

M

L

H

M

L

Total cooling power 7°C (1)

kW

2.79

2.38

1.82

4.46

3.80

2.91

7.25

6.17

4.72

Sensible cooling power

kW

2.02

1.72

1.32

3.22

2.74

21.0

5.25

4.47

3.42

Water flow rate

l / min

8.0

6.8

5.2

12.0

10.2

7.8

20.0

17.0

13.0

Pressure drop FALKO OC only

kPa

36

26

16

32

24

14

46

33

19

Pressure drop kit 2 or 3 ways kvs=4

kPa

1.4

1.0

0.6

3.2

2.3

1.3

9.1

6.4

3.7

Heating power 45 °C (2)

kW

3.36

2.87

2.19

5.38

4.58

3.50

8.73

7.43

5.68

Water flow rate

l / min

10

8.2

6.3

15.0

12.3

9.4

25.0

20.5

15.7

Pressure drop FALKO OC only

kPa

58

38

26

51

34

20

72

48

28

Pressure drop kit 2 or 3 ways kvs=4

kPa

2.2

1.5

1.0

5.0

3.4

2.0

14

9.2

5.4

Rated air flow

mc / h

510

382

255

850

640

425

1360

1020

680

Air Nominal Head

Pa

30

30

30

30

30

30

30

30

30

Sound pressure (*)

dB (A)

42

<42

<42

46

<46

<46

48

<48

<48

Power supply-protection grade.

V / ph/ Hz

     

230/1 + N/50----IP23

     

Electrical consumption

W

59

41

27

87

65

44

156

118

81

Maximum current

A

0.33

0.23

0.15

0.38

0.37

0.25

0.89

0.67

0.47

Hydraulic Connections

inch

   

¾ F” (DN 20)

   

Water content

Liters

                 

Condensate drainage pipe

mm

    

DN 20

    

Maximum operating pressure

MPa

    

1.6

    

Net Weight

Kg

 

16.4

 
 

18.9

 
 

26

 
  • Inlet water 7°, T 5 °C, Temp. Room 27 °C UR 47% (UNI EN 1397 :2015)
  • Inlet water 45°, T 5 °C Temp. Room 20 °C (UNI EN 1397:2015)
  • Sound pressure (dBA) r=1.5m, Q=1 (UNI EN ISO 3741:2010) H= max speed M= medium speed L= low speed
  •  
Headings of specifications

Cod. TCM05A — Fancoil Falko Ceiling 510 OC Standard

Hydronic terminal for ceiling mounting, composed of high efficiency copper-aluminum exchange battery with spindle finned package, frame internally covered with sound absorbent material. With quiet fan assembly. Three-speed control by live inputs. Complete with condensate collection tray and thin weft synthetic removable filter. Nominal air flow rate 510 m3/h, thermal power in cooling 2'788 W, heating 3'360 W. Height: 240 mm. Hydraulic connections 3/4” M.

Cod. TCM08A — Fancoil Falko Ceiling 850 OC Standard

Hydronic terminal for ceiling mounting, composed of high efficiency copper-aluminum exchange battery with spindle finned package, frame internally covered with sound absorbent material. With quiet fan assembly. Three-speed control by live inputs. Complete with condensate collection tray and thin weft synthetic removable filter. Nominal air flow 850 m3/h, thermal power in cooling 4'460 W, heating 5'375 W. Height: 240 mm. Hydraulic connections 3/4” M.

Cod. TCM14A — Fancoil Falko Ceiling 1360 OC Standard

Hydronic terminal for ceiling mounting, composed of high efficiency copper-aluminum exchange battery with spindle finned package, frame internally covered with sound absorbent material. With quiet fan assembly. Three-speed control by live inputs. Complete with condensate collection tray and thin weft synthetic removable filter. Nominal air flow rate 1'360 m3/h, thermal power in cooling 7'248 W, heating 8'734 W. Height: 240 mm. Hydraulic couplings 3/4” M.

 
Installation diagrams/Charts

Fan head curves: 

231fff.jpg

4353fff.png

Pressure drop Falko OC only

adads666.jpg

Pressure drop OC with 2 or 3 w kit

adas777.jpg

 

 
Download

Files:
(1 vote)

Brochure con le informazioni utili su Kers Evo

Date 2014-07-31
File Size 1.76 MB
Download 134,451

pdf.pngScheda tecnica recuperatore kers EvoHOT
(0 votes)
Date 2014-02-07
File Size 553.55 KB
Download 2,430
Only registered and logged in users can download this file.

 
 


Related products